Mini Fire Storage Tanks Perfluorinated Hexanone Cylinders
ISO9809-3 150bar Small fire tanks perfluorohexanone gas cylinders
1. Fill gas: perfluorohexanone
2. Aliases: Perfluorinated Hexanone cylinders, Fire Protection Cylinder, Storage Tank Fire Fighting, Mini Fire Gas Tanks, Mini Fire Gas Tanks, Fire Cylinder
Tips for safe use of gas cylinders:
Fire detection tube perfluorohexanone automatic fire extinguishing system is a new type of non-electric automatic operation automatic fire extinguishing system, also known as the temperature sensor automatic operation fire extinguishing equipment, is by the fixed fire extinguisher to provide the source according to the stable fire detection tube connected with it to immediately detect the fire, transport and ejects perfluorohexanone extinguishing agent.
Then to the safety protection area ejects a certain amount of fire extinguishing agent to make it evenly filled with all danger areas, pouring fire extinguishing automatic system.
Perfluorohexanone cylinders are mainly used in fire extinguishing installations.
Perfluorohexanone is colorless and tasteless transparent liquid at room temperature, which is rapidly transformed into gas after being sprayed by the nozzle. Therefore, the automatic fire extinguishing device of perfluorohexanone is also known as the automatic fire extinguishing system of gas.
According to the different driving pressure, it can be divided into non-stored pressure and stored pressure perfluorohexanone. Skool non-stored pressure perfluorohexanone fire-extinguishing device is a new fire-extinguishing device specially designed for fire protection in small space and specific space.
Mini Fire Storage Tanks Perfluorinated Hexanone Cylinders
Product parameters table(ISO9809-3)
Type | Outside Diameter (mm) | Water Capacity (L) | Bottle Height (mm) | Weight (kg) | Working pressure (Bar) | Design wall thickness (mm) | Material Grades |
89-1L-150 | 89 | 1 | 240 | 1.83 | 150 | 2.4 | 37MN |
89-1.4L-150 | 89 | 1.4 | 310 | 2.30 | 150 | 2.4 | 37MN |
108-2.0L-150 | 108 | 2 | 310 | 3.62 | 150 | 2.9 | 37MN |
108-2.5L-150 | 108 | 2.5 | 374 | 4.29 | 150 | 2.9 | 37MN |
108-3.0L-150 | 108 | 3.0 | 440 | 4.96 | 150 | 2.9 | 37MN |
108-5.0L-150 | 108 | 5.0 | 696 | 7.74 | 150 | 2.9 | 37MN |
140-3.4L-150 | 140 | 3.4 | 324 | 5.3 | 150 | 3.8 | 37MN |
140-4.0L-150 | 140 | 4.0 | 375 | 5.89 | 150 | 3.8 | 37MN |
140-5.0L-150 | 140 | 5.0 | 447 | 6.96 | 150 | 3.8 | 37MN |
140-6.3L-150 | 140 | 6.3 | 540 | 7.88 | 150 | 3.8 | 37MN |
140-6.7-150 | 140 | 6.7 | 569 | 8.30 | 150 | 3.8 | 37MN |
140-8.0L-150 | 140 | 8.0 | 665 | 9.68 | 150 | 3.8 | 37MN |
140-9.0L-150 | 140 | 9.0 | 744 | 10.7 | 150 | 3.8 | 37MN |
140-10.0L-150 | 140 | 10.0 | 818 | 11.9 | 150 | 3.8 | 37MN |
159-8.0L-150 | 159 | 8.0 | 548 | 9.11 | 150 | 4.3 | 37MN |
159-10.0L-150 | 159 | 10.0 | 660 | 10.9 | 150 | 4.3 | 37MN |
159-12.0L-150 | 159 | 12.0 | 780 | 13.1 | 150 | 4.3 | 37MN |
159-13.4L-150 | 159 | 13.4 | 861 | 15.4 | 150 | 4.3 | 37MN |
159-15.0L-150 | 159 | 15.0 | 932 | 16.8 | 150 | 4.3 | 37MN |
180-20.0L-150 | 180 | 20.0 | 1012 | 24.8 | 150 | 4.9 | 37MN |
Perfluorohexanone fire extinguishing device adopts small cylinder filling agent, integrated, miniaturized design, modular assembly, can be used in a single set, or multi-group integrated use, suitable for power distribution cabinet, energy storage power station, battery box, data cabinet and other small space fire protection use. In the future, hfC-227ea fire extinguishing equipment can be replaced